UK Fire Consultancy Ltd
07816 825230 Request a survey

Fire compliance that holds up to scrutiny.

Fire risk assessments, compartmentation, fire door and fire stopping surveys, with remedial work available from the same team that wrote the report. Led by Harry Batchu, BM TRADA Q-Mark certified, 20+ years on fire doors.

What the law asks of you

Two pieces of legislation put the obligation on the building's responsible person, not on a contractor. Both are worth knowing before an inspection makes them urgent.

A current fire risk assessmentRegulatory Reform (Fire Safety) Order 2005

The responsible person for a building must carry out a fire risk assessment and keep it under regular review. It applies to virtually all non-domestic premises and to the common parts of residential buildings.

A refurbishment, a change of use, or a new tenant layout can leave an assessment out of date fast. An assessment that no longer reflects the building isn’t a current one.

Fire doors checked on a fixed cycleFire Safety (England) Regulations 2022

Since 23 January 2023, in multi-occupancy residential buildings above 11 metres, fire doors in the common parts must be checked quarterly, and flat entrance doors annually on a best-endeavours basis.

Checks need a record. A door-by-door schedule with photographic evidence is what stands up when someone asks to see it.

Compartmentation that is actually intactVerified by survey, not assumption

Fire compartments are routinely breached by cabling, pipework and ductwork installed long after handover: above ceilings, inside risers, in roof voids. A standard fire risk assessment samples; it does not open up.

Where compartmentation drawings are missing or out of date, a dedicated survey is the only way to know what you have.

Four services, fully evidenced

Each one scoped, surveyed and closed out with a clear deliverable. Fees are quoted per building following a short scoping call.

01 Inspector completing a fire risk assessment beside a fire exit sign and call point

Fire Risk Assessment

Means of escape, detection and warning, emergency lighting, compartmentation, ignition and fuel sources, and the management arrangements that keep it all working.

Written report

Significant findings, risk-rated, with a prioritised action plan and a stated review date.

02 Surveyor torch-checking a fire-stopped cable and duct penetration through a compartment wall

Compartmentation Survey

Fire-resisting walls, floors, ceilings, protected shafts and voids, together with the doors and service penetrations passing through them.

Photos, drawings + report

Each report comes with a photographic survey, layout drawings and a written report, with every breach tagged to its location and ranked for remedial priority.

03 Technician measuring a fire door frame gap beside a fire door keep shut sign

Fire Door Survey & Remedial

We inspect leaf and frame gaps, intumescent and smoke seals, self-closing devices, hinges, glazing, ironmongery and signage, door by door.

Door schedule + works

Condition and compliance status per doorset, with remedials carried out under Q-Mark certification.

04 Surveyor checking sealed service penetrations against photographic evidence on a tablet

Fire Stopping Survey & Remedial

Penetration seals, linear gap seals and cavity barriers: the elements most often disturbed by later cabling and pipework.

Survey + reinstatement

Breaches evidenced, then sealed to reinstate the fire-resisting integrity of the element.

How a job runs

Every job includes the site visit and the report. If you want the findings put right, remedial works and a post-completion visit are available on request, carried out by the same team.

Step 01

Site attendance

A scoping call, then a site visit. Access to voids and risers agreed in advance so nothing is left unsurveyed.

Step 02

Report issued

Findings are written up with photographic evidence, risk-rated and prioritised, so you know what to fix first.

Step 03Optional

Remedial works

If requested, fire door and fire stopping remedials carried out directly, under the same certification the survey was made against.

Step 04Optional

Post-completion visit

Once works are finished, a return visit on request to check them and sign off, with closing records you can hand to an inspector, insurer or tenant.

Overseen by Harry, start to finish

UK Fire Consultancy is led by Harry Batchu, working with a team of associate consultants. Harry or a UKFC operative attends the site, and every report and completed job is reviewed and approved by Harry before it reaches you.

Read Harry's full story

Who we work with

Housing associationsCommon parts, flat entrance doors
Care & nursing homesCompartmentation, door schedules
Commercial & officesRisk assessments, fire stopping
Contractors & developersHandover and remedial packages

Certified, not just claimed

Every fire door survey and remedial job is carried out under recognised third-party certification.

Certification
BM TRADA Q-Mark
Accreditation
UKAS 0012
Fire stopping
NAPFIS 1736/27257
BM TRADA Q-Mark certification for Fire Door Installation and Fire Door Maintenance, shown with the UKAS Product Certification mark, certificate 0012
NAPFIS ISO 9001:2015 registered company certification, QAS International, certificate CA15019, the home of passive fire control

Book a survey, or just ask where to start.

Not sure whether you need a risk assessment, a compartmentation survey, or both? Say what the building is and Harry will tell you straight.

Telephone
07816 825230
Coverage
United Kingdom
Company no.
16691918
VAT no.
501 0885 27